The Frodo IEC cable

Important notes

Construction

You need the following parts to build this cable:

Step 1. Solder one end of the cable onto the DIN plug.

Step 2. Solder the other end of the cable onto the parallel plug. You should have the following connections:

DIN plug Parallel plug
2, GND 25, GND
4, CLK 8, D6
5, DATA 9, D7

Step 3. Build the inverter bridges, using the inverter IC. You should have the following connections:

DIN plug Inverter IC Inverter IC Parallel plug
3, ATN 2, Output 1 1, Input 1 5, D3
4, CLK 4, Output 2 3, Input 2 6, D4
5, DATA 6, Output 3 5, Input 3 7, D5

This is equivalent with three inverters whose outputs are pointing towards the pins in the left column of the table and their inputs to the ones on the right.

To make soldering on the IC easier, you may want to slightly melt the plastic on the inner side of the case of parallel port plug and carefully embed the IC into it.

Step 4. Supply power for the inverter IC, by connecting it to the parallel port. You should have the following connections:

Inverter IC Parallel plug
7, GND 25, GND
14, +5V 14, +5V

Step 5. Place the pull up resistors. You should have the following connections:

DIN plug Parallel plug
3, ATN 14, +5V
4, CLK 14, +5V
5, DATA 14, +5V

There must be a resistor on each connection but you shouldn't directly connect the pins of the DIN plug together.

Circuit diagram

[Frodo IEC cable]

The numbers besides the inverters show the suggested pin numbers of the inverter IC. You don't have to exactly follow these pin numbers though as the IC has six independent inverters which are all equivalent.

You can find the description of all parts used on the diagrams at the legend page.