Patch Name: PHSS_23679 Patch Description: s700_800 10.20 OV ITO5.3X IRIX Agent Patch A.05.37 Creation Date: 01/04/09 Post Date: 01/04/19 Hardware Platforms - OS Releases: s700: 10.20 s800: 10.20 Products: OpenView IT/Operations 5.3 Filesets: OVOPC-CLT-ENG.OVOPC-SGI-CLT,A.05.30 Automatic Reboot?: No Status: General Release Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_23679 Symptoms: PHSS_23679: - Installing UNIX agents from an ITO server which has no transition link from /bin to /usr/bin will leave a temporay file /tmp/remsh.out and an error message in the install.log file: ... opcping: '/bin/rm' not found - Problems with allowed port range. - When executing large numbers of autoactions, some of them were staying in 'running' state. - In case of an error the ITO Agent might hang during startup without terminating Defect Description: PHSS_23679: check the list of the symptoms SR: H555003277 B555007709 B555001737 8606141434 Patch Files: /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcnsl /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/perf_alxp.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/mwa_read.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/opcfwtmp.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/actions/mailq_pr.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/actions/st_inetd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/actions/st_mail.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/actions/pv.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/AgentPlatform /opt/OV/OpC/examples/progs/Makef.irix what(1) Output: /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcrclchk: HP OpenView IT/Operations A.05.37 (04/06/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcrdschk: HP OpenView IT/Operations A.05.37 (04/06/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcrndchk: HP OpenView IT/Operations A.05.37 (04/06/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcroschk: HP OpenView IT/Operations A.05.37 (04/06/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcrverchk: HP OpenView IT/Operations A.05.37 (04/06/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcrinst: HP OpenView IT/Operations A.05.37 (04/06/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/install/opcnsl: HP OpenView IT/Operations A.05.37 (04/06/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/perf_alxp.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/mwa_read.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/monitor/opcfwtmp.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/actions/mailq_pr.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/actions/st_inetd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/actions/st_mail.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/actions/pv.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/cmds/opcdf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/cmds/opclpst.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/A.05.37/RPC_NCS/cmds/opcps.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sgi/mips/ irix/AgentPlatform: None /opt/OV/OpC/examples/progs/Makef.irix: None cksum(1) Output: 966482765 3023667 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/opc_pkg.Z 3125392168 27021 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/install/ opcrclchk 1781491817 28235 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/install/ opcrdschk 2587019906 29670 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/install/ opcrndchk 1380397323 6053 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/install/ opcroschk 331496291 27987 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/install/ opcrverchk 743287527 111376 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/install/ opcrinst 3478241170 25452 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/install/opcnsl 2120262537 2551 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/monitor/ ana_disk.sh.Z 999697045 5961 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/monitor/ cpu_mon.sh.Z 3502268954 5944 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/monitor/ disk_mon.sh.Z 2384418054 5839 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/monitor/ last_logs.sh.Z 1764573495 5821 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/monitor/ mailq_l.sh.Z 1924249850 3154 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/monitor/ perf_alxp.sh.Z 975403863 6185 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/monitor/ proc_mon.sh.Z 1984652420 5405 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/monitor/ sh_procs.sh.Z 1636863157 5728 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/monitor/ swap_mon.sh.Z 1759557293 5654 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/monitor/ vp_chk.sh.Z 1595466597 5827 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/monitor/ mwa_read.sh.Z 2150287227 9541 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/monitor/ opcfwtmp.Z 2012999747 2524 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/actions/ mailq_pr.sh.Z 94523224 2612 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/actions/ st_inetd.sh.Z 3220520712 2747 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/actions/ st_mail.sh.Z 2861860406 5761 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/actions/pv.sh.Z 934326957 319 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/cmds/opcdf.Z 3091779907 384 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/cmds/opclpst.Z 1118181556 395 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/A.05.37/RPC_NCS/cmds/opcps.Z 182330930 4334 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sgi/mips/irix/AgentPlatform 2335343146 1159 /opt/OV/OpC/examples/progs/Makef.irix Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: PHSS_23680: s700: 11.00 s800: 11.00 Patch Package Size: 3400 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_23679 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_23679.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_23679. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_23679.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_23679.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o You may use this patch with the following official ITO release: A.05.30 o DO NOT use this patch with older releases of ITO, for example versions A.05.00 or A.05.11. o This patch provides the HP OV IT/Operations Intelligent Agent to be used with a ITO A.05.30 Management Server system, English and Japanese version. (A) Patch Installation Instructions ------------------------------- (A1) Install the patch, following the standard installation instructions. ------------------------------------------------------ NOTE: For backing up the system before installing a patch, you may use opc_backup(1m). NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWINSTALL. NOTE: Don't be afraid of the '-x autoreboot=true' option above. There won't be a reboot due to this ITO patch. You can skip this option if you like. NOTE: This patch must be installed on the ITO Management Server system, NOT on an ITO Managed Node directly. Changes will take effect on managed nodes by means of ITO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the ITO Administrator's Reference manual for more information. (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_23679 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. # swremove PHSS_23679