Patch Name: PHSS_22879 Patch Description: s700_800 10.20 OV ITO6.0X HP-UX 10.x Agent Patch A.06.03 Creation Date: 01/03/13 Post Date: 01/03/15 Warning: 01/04/05 - This Non-Critical Warning has been issued by HP. - PHSS_22879 introduces behavior that can cause communication failures in firewall environments for VPO's communications that need to go through the firewall. This is the result of source (client) port restrictions being ignored. Observe that destination (server) port restrictions are correctly handled. - This behavior does not affect non-firewall environments or firewall configurations that do not use source port restrictions. - To avoid this problem, HP recommends that PHSS_22879 be removed from all systems that operate in firewall environments that require source port restrictions and that can not wait for PHSS_23819 to become available. Patch PHSS_22879 should also be removed from software depots that are used to install patches on these systems. Patch PHSS_22879 should not be removed from non-firewall environments. - If PHSS_22879 can not be removed then the incorrect behavior can be corrected by applying the HP-UX 10.x Agent Patch PHSS_23819. PHSS_23819 is expected to be released by April 13, 2001. - The previous patch, PHSS_22010, does not exhibit this same behavior. PHSS_22010 will be re-released until a replacement patch is available. To ensure that as many other known issues as possible are addressed, HP recommends that PHSS_22010 be installed after PHSS_22879 is removed. If PHSS_22010 was installed prior to PHSS_22879, it will automatically be restored when PHSS_22879 is removed and will not need to be re-installed. - Please note that after PHSS_22879 is removed from the ITO Management Server, the ITO HP-UX 10.X agent must be redistributed to the HP-UX 10.X clients. Hardware Platforms - OS Releases: s700: 10.20 s800: 10.20 Products: OpenView IT/Operations 6.0 Filesets: OVOPC-CLT.OVOPC-UX10-CLT,A.06.00 Automatic Reboot?: No Status: General Superseded With Warnings Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_22879 Symptoms: PHSS_22879: - Changes were required for the security add-on product VantagePoint Advanced Security. - agent installation configure script fails to convert ITO 4 queue files: awk syntax error in swagent.log file PHSS_22010: - disk_mon.sh returns invalid values if the bdf command returns more than one line output for a filesystem (e.g. if the filesystem name exceeds its column width) - Several changes for firewall environments. For detailed information refer to the VPO Firewall Configuration White Paper version 3.0 - When executing large numbers of autoactions, some of them were staying in 'running' state. - opctrapi aborts after getting traps with unresolvable IP address. - The handling of '\' was different in the pattern definition and the "matching pattern". - if buffer file size limitation is enabled the agent may discard low-severity messages even if there is still space in the buffer file Defect Description: PHSS_22879: check the list of the symptoms PHSS_22010: check the list of the symptoms SR: B555009152 B555008613 B555008314 B555007752 B555007709 B555007602 B555007426 B555006890 B555006267 8606137088 Patch Files: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/dist_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/mondbfile.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ssp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/opcfwtmp.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/opcnprcs.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ opc_get_ems_resource.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/actions/mailq_pr.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/actions/st_inetd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/actions/st_syslogd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/actions/st_mail.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/actions/dist_del.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/cmds/E10000Log.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/cmds/ssp_config.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/AgentPlatform /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux10/AgentPlatform what(1) Output: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/install/opcrclchk: HP OpenView VantagePoint A.06.03 (02/14/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/install/opcrdschk: HP OpenView VantagePoint A.06.03 (02/14/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/install/opcrndchk: HP OpenView VantagePoint A.06.03 (02/14/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/install/opcroschk: HP OpenView VantagePoint A.06.03 (02/14/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/install/opcrverchk: HP OpenView VantagePoint A.06.03 (02/14/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/install/opcrinst: HP OpenView VantagePoint A.06.03 (02/14/01) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/dist_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/mondbfile.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ssp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/opcfwtmp.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/opcnprcs.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ opc_get_ems_resource.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/actions/mailq_pr.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/actions/st_inetd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/actions/st_syslogd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/actions/st_mail.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/actions/dist_del.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/cmds/opcdf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/cmds/opclpst.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/cmds/opcps.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/cmds/E10000Log.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/cmds/ssp_config.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/A.06.03/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux10/AgentPlatform: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux10/AgentPlatform: None cksum(1) Output: 1426758660 7509526 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/opc_pkg.Z 549947403 6898 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/install/ opcrclchk 2873125364 28659 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/install/ opcrdschk 1045260605 6734 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/install/ opcrndchk 2798385959 6287 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/install/ opcroschk 1107600480 32236 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/install/ opcrverchk 1315316847 105784 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/install/ opcrinst 1507632593 2731 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ ana_disk.sh.Z 1153108917 5977 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ cpu_mon.sh.Z 3431123336 6113 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ disk_mon.sh.Z 1264682947 5847 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ last_logs.sh.Z 3842413466 5842 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ mailq_l.sh.Z 125526017 6008 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ proc_mon.sh.Z 2254766819 5884 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ swap_mon.sh.Z 3337310400 5439 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ sh_procs.sh.Z 44923687 5741 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ vp_chk.sh.Z 1648535914 6125 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ dist_mon.sh.Z 538649249 14386 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ mondbfile.sh.Z 316974996 5985 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ ssp_chk.sh.Z 3308619561 12402 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ opcfwtmp.Z 1498118547 9458 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ opcnprcs.Z 3288429598 17925 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/monitor/ opc_get_ems_resource.Z 1931806786 2537 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/actions/ mailq_pr.sh.Z 892609819 2581 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/actions/ st_inetd.sh.Z 691529804 2590 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/actions/ st_syslogd.sh.Z 1206499283 2582 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/actions/ st_mail.sh.Z 4060767072 6099 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/actions/ dist_del.sh.Z 3943412997 324 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/cmds/ opcdf.Z 3986935362 386 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/cmds/ opclpst.Z 768832386 401 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/cmds/ opcps.Z 2823941480 3322 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/cmds/ E10000Log.sh.Z 3619885336 3106 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/cmds/ ssp_config.sh.Z 1276834919 13151 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/A.06.03/RPC_DCE_TCP/cmds/ opc_sec_v.sh.Z 3885164851 6319 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux10/AgentPlatform 1491926144 6317 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s800/hp-ux10/AgentPlatform Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_22010 Equivalent Patches: ITOSOL_00065: sparcSOL: 2.6 2.7 2.8 PHSS_22880: s700: 11.00 s800: 11.00 Patch Package Size: 7810 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_22879 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_22879.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_22879. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_22879.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_22879.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o It provides bug fixes and enhancements for the VPO A.06.00 Management Server system. o DO NOT use this patch with older releases of ITO, for example versions A.05.00, A.05.11 or A.05.30 (A) Patch Installation Instructions ------------------------------- (A1) Install the patch, following the standard installation instructions. For backing up the system before installing a patch, you may use opc_backup(1m) NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the VPO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWINSTALL. Don't be afraid of the '-x autoreboot=true' option above. There won't be a reboot due to this VPO patch. You can skip this option if you like. NOTE: This patch must be installed on the VPO Management Server system, NOT on an VPO Managed Node directly. Changes will take effect on managed nodes by means of VPO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the VPO Administrator's Reference manual for more information. (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_22879 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. # swremove PHSS_22879