Patch Name: PHSS_21323 Patch Description: s700_800 10.X OV OB2.55 patch - CC packet Creation Date: 00/04/12 Post Date: 00/04/14 Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OmniBackII A.02.55 Filesets: OMNIBACK-II.OMNI-CC-P Automatic Reboot?: No Status: General Release Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_21323 Symptoms: PHSS_21323: Id = NSMex02991 GUI hangs when initializing media. Id = NSMex03140 Omnicp fails copying medium in MO device with an error: "/dev/rdsk/c5t5d0: Device type is not supported". Id = NSMex02989 Xomnimonitor core dumps when printing all sessions. Id = NSMex02818 Omnib command does not check return codes correctly. Id = NSMex01657 Some files are not restored, although no errors have been reported during the restore session. PHSS_19957: Id = NSMex02288 Scheduler does not store the information about the excluded dates correctly. PHSS_17297: Id = NSMbb21778 CLI omniabort fails aborting sessions started in year 2000. Id = HSLco11626 Resizing a dialog window on Japanese Motif GUI results in hang of OmniBack II. Id = NSMex01955 Omnirpt.pl report doesn't contain any useful info on HP-UX 11.x. Id = NSMbb16717 Host objects displayed twice or more in omnirpt.pl output. Id = NSMex01848 'omnirpt.pl -media_statistics' reports all zeros. Id = NSMex01694 Restoring the NT registry from the incremental backup fails. Id = NSMex01798 'omnimlist -device -catalog' reports "No query data found" despite the fact there are some Informix objects on the medium. Id = NSMex01825 Xomnimm 'Media Pools' GUI shows the message "Bad catalog access for message #3158 in set 11." PHSS_15870: Id = NSMex01315 Omnimm -preerase fails with "incorrect syntax". Id = NSMex01363 "-list_scratch_media" option for omnimm lists wrong media. Id = NSMex01408 Output of "omnimm -media_info MediumLabel -detail" reports message: "Bad catalog access for message #263 in set 39!" Id = NSMex01428 Omnimm -repository_update fails with an error "Starting Session Manager got bad options" Id = NSMex01425 Omnimm -list_pool shows copied tapes as "Bad" Id = NSMex01527 Omnir and omnidb commands report 'Object not found' if hostname resolution has been changed, when trying to access old object, created with previous hostname resolution. Id = NSMex01531 Cell Server remains in state 'Not connected' in xomnicellmon, if it once stops running. Id = NSMbb18903 omnimm -show_repository_alloc fails with an exit status 11 even if there are no errors. Id = HSLco10243 - "SR5003429571" Omnib failed with exit status "3" if datalist was incorrect. Id = NSMex01553 Xomniadmin coredumps when trying to add user while using NIS. Id = NSMex01645 OmniBack II Web reporting does not makes any report. PHSS_14349: Id = NSMex01042 It was possible to save barlist without having Access Right "Save datalist". Id = NSMex01001 Omnicellinfo coredumped if option -allbdf was used. Defect Description: PHSS_21323: Id = NSMex02991 When initializing media is done from the CS console, the system hangs right after the confirmation in the dialog box is clicked, if the Actions menu is left open. Resolution: Xomnimm fixed. Id = NSMex03140 MO devices are not recognized by the omnicp command, because the device type is not specified in the device table. Resolution: MO device type added to list of supported device types. Id = NSMex02989 Xomnimonitor core dumps when printing all sessions if there is a backup host whose name is more than 80 characters long. Resolution: Hostname can be now up to 120 characters long. Part of SSPUX255_151. Id = NSMex02818 Session status is "Completed" even if some of the agents were aborted. Resolution: Return codes are now correctly checked. Part of SSPUX255_147. Id = NSMex01657 If the limit of parameters for inet execution is exceeded, no error is reported. This can lead to some files missing after the restore has finished successfully. Resolution: The session is now aborted, if too many files are specified for restore. Part of SSPUX255_098. PHSS_19957: Id = NSMex02288 Excluded dates are not correctly written in the datalist. Part of the SSP255_138. Resolution: Fix implemented in xomnibackup. PHSS_17297: Id = NSMbb21778 When trying to run omniabort with short session ID syntax for a session in the year 2000, an error occurs: "Cannot connect to required session x." where x is the session ID. Resolution: Correction of transformation from short session IDs to long session IDs. Id = HSLco11626 Handling of resize in Japanese Motif environment runs into endless loop, and OmniBack II hangs. Part of SSP255_107. Resolution: New motif libraries have been linked. Id = NSMex01955 Perl script omnirpt.pl treats HP-UX 11.x system the same way as 9.x. Home directory for OB2 binaries is: /usr/omni/bin instead of /opt/omni/bin. Part of SSP255_119. Resolution: Checking for different OS has been improved in omnirpt.pl. Id = NSMbb16717 Perl script omnirpt.pl parses host objects in a wrong way. This produces the same object listed as many times as the object has been backed up in the output of omnirpt.pl. Part of SSP255_119. Resolution: Parsing of host backups has been fixed in omnirpt.pl. Id = NSMex01848 Incorrect handling of -media_statistics option produces output with zeros for all media statistic info. Part of SSP255_119. Resolution: Fix implemented in omnirpt.pl. Id = NSMex01694 GUI creates restore chain and does not allow the user to reboot the machine between full and incremental restores. Part of SSP255_104. Resolution: Fix implemented in xomnirestore. Id = NSMex01798 Omnimlist with option "-catalog" does not work correctly for the secong medium of Informix backup. If backup fills up one medium and continues to another one, the omnimlist command doesn't report the catalog for the second medium correctly. Part of SSP255_106. Resolution: Fix implemented in omnimlist command. Id = NSMex01825 Policy for Magazine pools not properly showed if 'Print' command is selected in Media Pools GUI (xomnimm). Part of SSP255_109. Resolution: Messaging improved in xomnimm. PHSS_15870: Id = NSMex01315 Omnimm -preerase of MO jukebox platters fails with "incorrect syntax". Part of SSP255_50. Id = NSMex01363 "-list_scratch_media" option for omnimm listed media that were not protected OR can be used for backup. Now it lists media that are not protected AND can be used for backup. Part of SSP255_53. Id = NSMex01408 Output of "omnimm -media_info MediumLabel -detail" reported message: "Bad catalog access for message #263 in set 39!" for medium type if medium is Full and has a Copy. Par of SSP255_55. Id = NSMex01428 Omnimm -repository_update failed with an error "Starting Session Manager got bad options" if it was started on AIX host. Part of SSP255_60. Id = NSMex01425 Omnimm -list_pool shows copied tapes as "Bad" Part of SSP255_63. Id = NSMex01527 If hostname resolution has been changed, and user tries to restore objects from old backups using command omnir, OmniBack II reports 'Object not found'. The same happens by querying the database (omnidb). Object's hostname is stored in the database the way as expanded at the backup time, and if hostname expansion changes (e.g. from short hostname to long hostname), objects are not the same at compare time. See NOTE for resolution. Part of SSP255_74. Id = NSMex01531 If a Cell Server stops running, the xomnicellmon loses the connection to it, and it is never reestablished, once the Cell Server comes up again. Part of SSP255_75. Id = NSMbb18903 If the logical device has defined "cleaning slot" then omnimm -show_repository_alloc always fails with an exit code 11. Part of SSP255_83. Id = HSLco10243 Omnib command failed with exit status "3" if datalist was incorrect. Now the exit status in such case is 12. Id = NSMex01553 Xomniadmin coredumped during the UserList browsing if the NIS was running on the system. Part of SSP255_86. Id = NSMex01645 OmniBack II Web reporting does not work if the Web Server is located on HP-UX 11.x. PHSS_14349: Id = NSMex01042 With A.02.55 it was possible to save barlist without having Access Right "Save datalist". If you selected the barlist -> "Backup selected ..." then it was possible to save the barlist. Part of SSP255_12. Id = NSMex01001 Omnicellinfo coredumped if option -allbdf and there was a host in the cell with lots of file-systems. Part of SSP255_15. SR: 5003429571 Patch Files: /opt/omni/databases/vendor/cc/dec/alpha/osf1-4/A.02.55/ packet.Z /opt/omni/databases/vendor/cc/hp/s800/hp-ux/A.02.55/packet.Z /opt/omni/databases/vendor/cc/hp/s800/hp-ux-10/A.02.55/ packet.Z /opt/omni/databases/vendor/cc/hp/s800/hp-ux-1020/A.02.55/ packet.Z /opt/omni/databases/vendor/cc/ibm/rs6000/aix/A.02.55/ packet.Z /opt/omni/databases/vendor/cc/ibm/rs6000/aix-42/A.02.55/ packet.Z /opt/omni/databases/vendor/cc/sco/i386/sco_sv/A.02.55/ packet.Z /opt/omni/databases/vendor/cc/sgi/mips/irix/A.02.55/packet.Z /opt/omni/databases/vendor/cc/sgi/mips/irix-62/A.02.55/ packet.Z /opt/omni/databases/vendor/cc/siemens/r400/sinix/A.02.55/ packet.Z /opt/omni/databases/vendor/cc/sun/sparc/solaris/A.02.55/ packet.Z /opt/omni/databases/vendor/cc/sun/sparc/sunos/A.02.55/ packet.Z what(1) Output: /opt/omni/databases/vendor/cc/dec/alpha/osf1-4/A.02.55/ packet.Z: None /opt/omni/databases/vendor/cc/hp/s800/hp-ux/A.02.55/ packet.Z: None /opt/omni/databases/vendor/cc/hp/s800/hp-ux-10/A.02.55/ packet.Z: None /opt/omni/databases/vendor/cc/hp/s800/hp-ux-1020/A.02.55/ packet.Z: None /opt/omni/databases/vendor/cc/ibm/rs6000/aix/A.02.55/ packet.Z: None /opt/omni/databases/vendor/cc/ibm/rs6000/aix-42/A.02.55/ packet.Z: None /opt/omni/databases/vendor/cc/sco/i386/sco_sv/A.02.55/ packet.Z: None /opt/omni/databases/vendor/cc/sgi/mips/irix/A.02.55/ packet.Z: None /opt/omni/databases/vendor/cc/sgi/mips/irix-62/A.02.55/ packet.Z: None /opt/omni/databases/vendor/cc/siemens/r400/sinix/A.02.55/ packet.Z: None /opt/omni/databases/vendor/cc/sun/sparc/solaris/A.02.55/ packet.Z: None /opt/omni/databases/vendor/cc/sun/sparc/sunos/A.02.55/ packet.Z: None cksum(1) Output: 964851009 2755053 /opt/omni/databases/vendor/cc/dec/alpha/ osf1-4/A.02.55/packet.Z 3735378372 8574884 /opt/omni/databases/vendor/cc/hp/s800/ hp-ux/A.02.55/packet.Z 1101467711 8761844 /opt/omni/databases/vendor/cc/hp/s800/ hp-ux-10/A.02.55/packet.Z 2684336919 13965524 /opt/omni/databases/vendor/cc/hp/s800/ hp-ux-1020/A.02.55/packet.Z 4124830080 2017467 /opt/omni/databases/vendor/cc/ibm/rs6000/ aix/A.02.55/packet.Z 2313404064 2031147 /opt/omni/databases/vendor/cc/ibm/rs6000/ aix-42/A.02.55/packet.Z 1325393148 2075332 /opt/omni/databases/vendor/cc/sco/i386/ sco_sv/A.02.55/packet.Z 999878310 2626445 /opt/omni/databases/vendor/cc/sgi/mips/ irix/A.02.55/packet.Z 1400258191 3443615 /opt/omni/databases/vendor/cc/sgi/mips/ irix-62/A.02.55/packet.Z 269505302 2643229 /opt/omni/databases/vendor/cc/siemens/ r400/sinix/A.02.55/packet.Z 2284749901 2410403 /opt/omni/databases/vendor/cc/sun/sparc/ solaris/A.02.55/packet.Z 1443352571 4941697 /opt/omni/databases/vendor/cc/sun/sparc/ sunos/A.02.55/packet.Z Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_14349 PHSS_15870 PHSS_17297 PHSS_19957 Equivalent Patches: PHSS_21324: s700: 11.00 s800: 11.00 Patch Package Size: 55010 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_21323 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_21323.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_21323. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_21323.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_21323.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: PHSS_21323: NOTE! Patch has to be installed on the Cell Server host. The Cell Console packet needs to be redistributed to the appropriate systems, where the Cell Consoles are installed before the patch modifications take effect. This can be done from within the "Cell Administration - Install" window of the OmnibackII graphical user interface. Option -noexpand has been added to commands omnidb and omnir in order to avoid hostname expanding, when hostname resolution at backup time is different than at query or restore time. The correct syntax for Object is (check man page for complete syntax, and see here for Object syntax): omnidb Object -sess session .... Object = [-noexpand] ( -filesystem Host:MountPoint Label | -vbfs Host:MountPoint Label | -omnidb Host:MountPoint Label | -rawdisk Host Label | -sap Host:Set ) -stream Host:Set | -oracle Host:Set | -sybase Host:Set ) Option -list_appendable_media has been added to omnimm command. Omnimm -list_appendable_media reports all appendable media per pool. Usage: omnimm -list_appendable_media PoolName NOTE: New option is not listed in help. PHSS_14349/PHSS_14350 * "omnicellinfo -allbdf" failed if the sum of characters of all filesystem names on one host was bigger than 1024 bytes. In PHSS_14349/PHSS_14350 this limit was increased to 8192 bytes. Patch includes the following Site Specific Patches: SSPUX255_012 SSPUX255_015 SSPUX255_050 SSPUX255_053 SSPUX255_055 SSPUX255_060 SSPUX255_063 SSPUX255_074 SSPUX255_075 SSPUX255_083 SSPUX255_086 SSPUX255_098 SSPUX255_101 SSPUX255_104 SSPUX255_106 SSPUX255_107 SSPUX255_109 SSPUX255_119 SSPUX255_138 SSPUX255_147 SSPUX255_151