Patch Name: PHSS_16457 Patch Description: s700_800 10.X OV ITO4.0X HP-UX 9.x Agent Patch Creation Date: 98/10/27 Post Date: 98/10/28 Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OpenView IT/Operations 4.0 Filesets: OVOPC-CLT.OVOPC-UX-CLT78 Automatic Reboot?: No Status: General Release Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_16457 Symptoms: PHSS_16457: - The <$MSG_ID> variable is not set correctly in monitor conditions. - Scheduled actions are scheduled for the following month if weekday is specified. - Usage of the opcmsg() API may cause the application to abort. - Message agent sometimes stays in the buffering state forever. - The opcfwtmp command returns UTC time instead of local time. - The logfile encapsulator might coredump when tracing is turned on and very long messages are generated. - The logfile encapsulator suddenly starts growing to the kernel limit and coredumps. PHSS_15267: - opcmsga error: bulk transfer from agent to server may fail with 'interrupted system call' for agents using NCS communication. - Scheduled actions are not executed at 00:xx in April - 'opcagt -status' sometimes hangs - logfile encapsulator problem: truncated message appear in the browser - agent installation fails if there is no opc_op user, but opcgrp is already in NIS or NIS+. - agent didn't work with ECS (Event Correlation) version A.02.15 (which is needed for Y2K compliance) PHSS_14251: - Multiple message (opcmsg) templates get intermixed condition processing. This happens when an agent has multiple opcmsg templates assigned. In this case the contents of matched messages can resemble messages that should actually get supressed. Other symptoms of this bug can be a core dumping message interceptor (opcmsgi) or message agent (opcmsga). - Monitor agent does not use the pipe monagtp, so the growing pipe wastes network/streams buffer resources. PHSS_12687: - Distribution agent coredumps when distributing ECS circuits. - Error during subagent installation: Can't create tmp files. - If respmgr file contains short hostname of the managment server or the OPC_RESOLVE_IP switch is enabled the send_data from the management server fails. Defect Description: PHSS_16457: check the list of the symptoms PHSS_15267: check the list of the symptoms PHSS_14251: check the list of the symptoms PHSS_12687: check the list of the symptoms SR: 1653272344 5003396960 1653259317 Patch Files: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/perf_alxp.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/mwa_read.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/dist_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/ltf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/lbtf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/opcnprcs.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/perf_alxp.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/mwa_read.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/dist_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/ltf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/lbtf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/opcnprcs.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/cmds/opc_sec_v.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/actions/mailq_pr.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/actions/st_inetd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/actions/st_mail.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/actions/pv.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/actions/dist_del.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/actions/itogpm.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/AgentPlatform /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux/AgentPlatform what(1) Output: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/install/opcrclchk: HP OpenView IT/Operations A.04.11 (10/13/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/install/opcrdschk: HP OpenView IT/Operations A.04.11 (10/13/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/install/opcrndchk: HP OpenView IT/Operations A.04.11 (10/13/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/install/opcroschk: HP OpenView IT/Operations A.04.11 (10/13/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/install/opcrverchk: HP OpenView IT/Operations A.04.11 (10/13/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/install/opcrinst: HP OpenView IT/Operations A.04.11 (10/13/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/install/opcrclchk: HP OpenView IT/Operations A.04.11 (10/14/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/install/opcrdschk: HP OpenView IT/Operations A.04.11 (10/14/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/install/opcrndchk: HP OpenView IT/Operations A.04.11 (10/14/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/install/opcroschk: HP OpenView IT/Operations A.04.11 (10/14/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/install/opcrverchk: HP OpenView IT/Operations A.04.11 (10/14/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/install/opcrinst: HP OpenView IT/Operations A.04.11 (10/14/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/perf_alxp.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/mwa_read.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/dist_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/ltf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/lbtf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/monitor/opcnprcs.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/perf_alxp.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/mwa_read.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/dist_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/ltf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/lbtf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_DCE_TCP/monitor/opcnprcs.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/cmds/opcdf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/cmds/opclpst.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/cmds/opcps.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/cmds/opc_sec_v.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/actions/mailq_pr.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/actions/st_inetd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/actions/st_mail.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/actions/pv.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/actions/dist_del.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.11/RPC_NCS/actions/itogpm.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/AgentPlatform: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux/AgentPlatform: None cksum(1) Output: 3884204391 4681046 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/opc_pkg.Z 4058420309 3000177 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/opc_pkg.Z 1127671623 27042 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/install/ opcrclchk 191889920 30752 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/install/ opcrdschk 3152374719 6526 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/install/ opcrndchk 1473086941 5915 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/install/ opcroschk 4073858294 29488 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/install/ opcrverchk 762022155 104759 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/install/ opcrinst 1574629395 27042 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/install/ opcrclchk 999457023 30752 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/install/ opcrdschk 3563625329 6526 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/install/ opcrndchk 2067622175 5915 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/install/ opcroschk 378122396 29488 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/install/ opcrverchk 2144163905 104737 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/install/ opcrinst 2821551529 2542 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ ana_disk.sh.Z 3612137129 6219 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ cpu_mon.sh.Z 1596457056 6645 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ disk_mon.sh.Z 1953044613 6289 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ last_logs.sh.Z 298813559 6276 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ mailq_l.sh.Z 1949273422 3172 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ perf_alxp.sh.Z 77793936 6460 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ proc_mon.sh.Z 1627086648 5897 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ sh_procs.sh.Z 1525827758 6403 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ swap_mon.sh.Z 1882085223 6139 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ vp_chk.sh.Z 1138940474 6312 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ mwa_read.sh.Z 2894891128 6565 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ dist_mon.sh.Z 1392985578 11180 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ltf.Z 1392985578 11180 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/lbtf.Z 1834586396 89679 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/monitor/ opcnprcs.Z 2821551529 2542 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ ana_disk.sh.Z 3612137129 6219 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ cpu_mon.sh.Z 1596457056 6645 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ disk_mon.sh.Z 1953044613 6289 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ last_logs.sh.Z 298813559 6276 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ mailq_l.sh.Z 1949273422 3172 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ perf_alxp.sh.Z 77793936 6460 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ proc_mon.sh.Z 1627086648 5897 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ sh_procs.sh.Z 1525827758 6403 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ swap_mon.sh.Z 1882085223 6139 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ vp_chk.sh.Z 1138940474 6312 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ mwa_read.sh.Z 2894891128 6565 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ dist_mon.sh.Z 3040362514 11309 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ ltf.Z 3040362514 11309 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ lbtf.Z 2266279488 7444 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_DCE_TCP/monitor/ opcnprcs.Z 909396310 318 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/cmds/opcdf.Z 2771356106 330 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/cmds/opclpst.Z 2598486652 356 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/cmds/opcps.Z 3415223968 13625 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/cmds/ opc_sec_v.sh.Z 3295398555 2525 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/actions/ mailq_pr.sh.Z 2218276543 2543 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/actions/ st_inetd.sh.Z 473817878 2558 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/actions/ st_mail.sh.Z 1162141366 6188 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/actions/pv.sh.Z 676034981 6529 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/actions/ dist_del.sh.Z 142056833 1374 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.11/RPC_NCS/actions/ itogpm.sh.Z 2629658785 4485 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/AgentPlatform 2447175323 4483 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s800/hp-ux/AgentPlatform Patch Conflicts: PHSS_16458 Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_12687 PHSS_14251 PHSS_15267 Equivalent Patches: None Patch Package Size: 8380 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_16457 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_16457.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_16457.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_16457. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_16457.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_16457.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o You may use this patch with the following official ITO releases: A.04.0x o DO NOT use this patch with older releases of OpC or ITO, for example versions A.01.X, A.02.X or A.03.X. o This patch provides the HP OV IT/Operations Intelligent Agent to be used with a ITO 4.0x Management Server system, Oracle, English and Japanese version. (A) Patch Installation Instructions ------------------------------- (A1) Install the patch, following the standard installation instructions. Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license restrictions and limitation of liability and warranties, before installing this patch. ------------------------------------------------------ 1. Back up your system before installing a patch. (you may use opc_backup) 2. Login as root. 3. Copy the patch to your /tmp directory and unshar it: # cd /tmp # sh PHSS_16457 4. For a standalone system, run swinstall to install the patch: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWINSTALL. # swinstall -x match_target=true \ -s /tmp/PHSS_16457.depot It is recommended that you move the PHSS_16457.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: # dd if=/tmp/PHSS_16457.depot of=/dev/rmt/0m bs=2k NOTE: This patch must be installed on the ITO Management Server system, NOT on an ITO Managed Node directly. Changes will take effect on managed nodes by means of ITO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the ITO Administrator's Reference manual for more information. (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_16457 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. # swremove PHSS_16457