Patch Name: PHSS_16146 Patch Description: s700_800 10.X OV ITA3.10 Server Patch Creation Date: 98/09/30 Post Date: 98/10/08 Hardware Platforms - OS Releases: s700: 10.01 10.10 10.20 s800: 10.01 10.10 10.20 10.30 Products: OpenView IT/Administration A.03.10 Filesets: ITA-SERVER.ITA-MGR-BIN ITA-GUI.ITA-GUI Automatic Reboot?: No Status: General Release Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_16146 Symptoms: PHSS_16146: 1. Synchronization ends with Done(Warning) when a product with a title containing "`" is discovered. 2. Discovery of Logical Volumes (LVs) and Volume Groups with "-" in their name fails. 3. ITA does not allow to create LVs with "-" in their name. 4. Problems with LVs with size 0. 5. Saving of queries and policies does not work when GUI was started through ITA-ITO Hotlink. 6. ITA tries to save queries and policies under "/". 7. Sometimes nothing happens after pressing OK in the "ITA: Change Audit Filter"-window. Defect Description: PHSS_16146: 1. The constraints in ITA A.03.00 don't allow a "`" in a product title. 2. The constraints in ITA A.03.00 don't allow a "-" in the name of a logical volume or a volume group. 3. see 2. 4. Discovery of LVs with size 0 ends with a warning. No actions possible with ITA on such objects. 5. When trying to save a query or policy in an ITA GUI started through the ITA-ITO Hotlink the customer gets the message: 70-3 : INTERNAL ERROR : Invalid method: the calling class is and the method class is $s. 6. Instead of saving a query or policy to /var/opt/OV/tmp/AdC/.query (resp. .policy) ITA A.03.10 tries to save it under /_var_opt_OV_tmp_AdC_.query (resp. .policy). With this patch the queries will be saved under /var/opt/OV/tmp/AdC/.query and the last saved policy will be stored in /var/opt/OV/tmp/AdC/.policy. 7. When selecting too many object in the "ITA: Change Audit Filter"-window an DB Connection Error occurs but it is not handled and displayed in the ITA GUI. SR: B700028688 B700028670 Patch Files: /opt/OV/bin/adcsvcode.im /opt/OV/newconfig/AdC/opt/OV/bin/adcgui.vue /opt/OV/newconfig/AdC/opt/OV/bin/adcgui.cde /opt/OV/newconfig/AdC/opt/OV/bin/itagui.vue /opt/OV/newconfig/AdC/opt/OV/bin/itagui.cde what(1) Output: /opt/OV/bin/adcsvcode.im: HP OpenView IT/Administration Patch PHSS_16146 Phas e: A.03.11.%7 is model compatible with: A. 03.00.% [ 2 ] (10/1/98) /opt/OV/newconfig/AdC/opt/OV/bin/adcgui.vue: HP OpenView IT/Administration, Version: A.03.11 PHSS _16146 (Sep/30/98,10:39) /opt/OV/newconfig/AdC/opt/OV/bin/adcgui.cde: HP OpenView IT/Administration, Version: A.03.11 PHSS _16146 (Sep/30/98,11:25) /opt/OV/newconfig/AdC/opt/OV/bin/itagui.vue: HP OpenView IT/Administration, Version: A.03.11 PHSS _16146 (Sep/30/98,10:39) HP OpenView Windows NNM Release B.05.01 HP 9000 S700/S800 HP-UX 10.x Copyright (c) 1990-1997 Hewlett-Packard Co., All Ri ghts Reserved. /opt/OV/newconfig/AdC/opt/OV/bin/itagui.cde: HP OpenView IT/Administration, Version: A.03.11 PHSS _16146 (Sep/30/98,11:25) HP OpenView Windows NNM Release B.05.01 HP 9000 S700/S800 HP-UX 10.x Copyright (c) 1990-1997 Hewlett-Packard Co., All Ri ghts Reserved. cksum(1) Output: 2804365577 32023788 /opt/OV/bin/adcsvcode.im 2160959950 4626635 /opt/OV/newconfig/AdC/opt/OV/bin/ adcgui.cde 667261216 4203463 /opt/OV/newconfig/AdC/opt/OV/bin/ adcgui.vue 2962716412 4861151 /opt/OV/newconfig/AdC/opt/OV/bin/ itagui.cde 1925976848 4442088 /opt/OV/newconfig/AdC/opt/OV/bin/ itagui.vue Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: ITA-SERVER.ITA-MGR-BIN,r=A.03.10,v=HP ITA-GUI.ITA-GUI,r=A.03.10,v=HP Supersedes: None Equivalent Patches: None Patch Package Size: 49080 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_16146 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_16146.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_16146.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_16146. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_16146.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_16146.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: Special Installation Instructions: ================================== 1. Ensure that the IT/Administration Server isn't running on the system where you want to install the patch. As user root: # /opt/OV/bin/ovstop adcsv This command will stop all ITA management server processes. 2. Ensure that there is no ITA GUI running on the system where you want to install the patch. Exit from all the running GUIs. 3. Install the patch as described in the "Installation Instructions".