Patch Name: PHSS_15675 Patch Description: s700_800 10.X OV ITO4.0X HP-UX 11.x Agent Patch Creation Date: 98/11/17 Post Date: 98/11/17 Repost: 99/02/26 A problem has been discovered with superseding patches PHSS_17356 and PHSS_17501. Those patches can cause problems with integrated applications on HP-UX 11.X clients. Patch PHSS_15675 does not exhibit the same problem and is being re-released until a replacement patch is available. Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OpenView IT/Operations 4.0 Filesets: OVOPC-CLT.OVOPC-UX11-CLT Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_15675 Symptoms: PHSS_15675: - The <$MSG_ID> variable is not set correctly in monitor conditions. - Agent reinstallation does not work from remote SD depot. - Scheduled actions are scheduled for the following month if weekday is specified. - Deinstallation of agent leaves files on system but no SD error messages. - Usage of the opcmsg() API may cause the application to abort. - Message agent sometimes stays in the buffering state forever. - The opcfwtmp command returns UTC time instead of local time. - The logfile encapsulator might coredump when tracing is turned on and very long messages are generated. - The logfile encapsulator suddenly starts growing to the kernel limit and coredumps. PHSS_13550: - changed hp/s700/hp-ux11 platform number PHSS_13027: - Adds support for HP-UX 11.00 for IT/Operations 4.0X Defect Description: PHSS_15675: check the list of the symptoms PHSS_13550: check the list of the symptoms PHSS_13027: check the list of the symptoms SR: 1653272344 5003396960 1653259317 Patch Files: /opt/OV/OpC/examples/progs/Makef.hpux11 /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/perf_alxp.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/mwa_read.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/dist_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/mondbfile.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/opcfwtmp.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/opcnprcs.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/actions/mailq_pr.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/actions/st_inetd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/actions/st_mail.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/actions/pv.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/actions/dist_del.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/actions/itogpm.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/AgentPlatform /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux11/AgentPlatform what(1) Output: /opt/OV/OpC/examples/progs/Makef.hpux11: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/install/opcrclchk: HP OpenView IT/Operations A.04.11 (11/04/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/install/opcrdschk: HP OpenView IT/Operations A.04.11 (11/04/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/install/opcrndchk: HP OpenView IT/Operations A.04.11 (11/04/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/install/opcroschk: HP OpenView IT/Operations A.04.11 (11/04/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/install/opcrverchk: HP OpenView IT/Operations A.04.11 (11/04/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/install/opcrinst: HP OpenView IT/Operations A.04.11 (11/04/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/perf_alxp.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/mwa_read.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/dist_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/mondbfile.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/opcfwtmp.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/monitor/opcnprcs.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/actions/mailq_pr.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/actions/st_inetd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/actions/st_mail.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/actions/pv.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/actions/dist_del.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/actions/itogpm.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/cmds/opcdf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/cmds/opclpst.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/cmds/opcps.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.04.11/RPC_DCE_TCP/cmds/opc_sec_v.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/AgentPlatform: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux11/AgentPlatform: None cksum(1) Output: 1089608637 1345 /opt/OV/OpC/examples/progs/Makef.hpux11 213773626 2995635 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/opc_pkg.Z 3458403852 6714 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/install/ opcrclchk 2288853935 28084 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/install/ opcrdschk 2056058636 6662 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/install/ opcrndchk 3489271379 6317 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/install/ opcroschk 2956306294 31076 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/install/ opcrverchk 2199992011 96468 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/install/ opcrinst 466022611 2552 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ ana_disk.sh.Z 1201513091 5881 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ cpu_mon.sh.Z 254641069 5897 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ disk_mon.sh.Z 882317057 5782 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ last_logs.sh.Z 2342272506 5727 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ mailq_l.sh.Z 3488070269 3152 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ perf_alxp.sh.Z 1284379659 5875 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ proc_mon.sh.Z 565959807 5339 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ sh_procs.sh.Z 2683904779 5823 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ swap_mon.sh.Z 1507937514 5585 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ vp_chk.sh.Z 3725037235 5764 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ mwa_read.sh.Z 996893325 6021 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ dist_mon.sh.Z 2291882909 12848 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ mondbfile.sh.Z 2700032278 9396 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ opcfwtmp.Z 446601696 8504 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/monitor/ opcnprcs.Z 871009320 2527 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/actions/ mailq_pr.sh.Z 4124148795 2546 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/actions/ st_inetd.sh.Z 315580348 2557 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/actions/ st_mail.sh.Z 4172559265 5688 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/actions/ pv.sh.Z 1159790019 5969 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/actions/ dist_del.sh.Z 1010043150 1371 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/actions/ itogpm.sh.Z 2835688803 320 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/cmds/ opcdf.Z 994990997 333 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/cmds/ opclpst.Z 3470634224 359 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/cmds/ opcps.Z 2428349200 13067 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.04.11/RPC_DCE_TCP/cmds/ opc_sec_v.sh.Z 3667200234 4897 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/AgentPlatform 3057721900 4895 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s800/hp-ux11/AgentPlatform Patch Conflicts: PHSS_16273 Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_13027 PHSS_13550 Equivalent Patches: None Patch Package Size: 3360 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_15675 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_15675.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_15675.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_15675. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_15675.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_15675.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o You may use this patch with the following official ITO releases: A.04.0x o DO NOT use this patch with older releases of OpC or ITO, for example versions A.01.X, A.02.X or A.03.X. o This patch provides the HP OV IT/Operations Intelligent Agent to be used with a ITO 4.0x Management Server system, Oracle, English and Japanese version. (A) Patch Installation Instructions ------------------------------- (A1) Install the patch, following the standard installation instructions. Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license restrictions and limitation of liability and warranties, before installing this patch. ------------------------------------------------------ 1. Back up your system before installing a patch. (you may use opc_backup) 2. Login as root. 3. Copy the patch to your /tmp directory and unshar it: # cd /tmp # sh PHSS_15675 4. For a standalone system, run swinstall to install the patch: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWINSTALL. # swinstall -x match_target=true \ -s /tmp/PHSS_15675.depot It is recommended that you move the PHSS_15675.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: # dd if=/tmp/PHSS_15675.depot of=/dev/rmt/0m bs=2k NOTE: This patch must be installed on the ITO Management Server system, NOT on an ITO Managed Node directly. Changes will take effect on managed nodes by means of ITO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the ITO Administrator's Reference manual for more information. (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_15675 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. # swremove PHSS_15675