Patch Name: PHSS_15672 Patch Description: s700_800 10.X OV ITO4.0X SUNOS Agent Patch Creation Date: 98/07/08 Post Date: 98/07/14 Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OpenView IT/Operations 4.0 Filesets: OVOPC-CLT-ENG.OVOPC-SOS-CLT Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_15672 Symptoms: PHSS_15672: - opcmsgi coredumps - problems with leap year calculation after year 2000 Defect Description: PHSS_15672: check the list of the symptoms SR: 0000000000 Patch Files: /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcnsl /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/perf_alxp.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/mwa_read.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/actions/mailq_pr.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/actions/st_inetd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/actions/st_mail.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/actions/pv.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/actions/itogpm.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/opcfwtmp.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/AgentPlatform /opt/OV/OpC/examples/progs/Makef.sunos what(1) Output: /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcrclchk: HP OpenView IT/Operations A.04.04 (06/24/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcrdschk: HP OpenView IT/Operations A.04.04 (06/24/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcrndchk: HP OpenView IT/Operations A.04.04 (06/24/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcroschk: HP OpenView IT/Operations A.04.04 (06/24/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcrverchk: HP OpenView IT/Operations A.04.04 (06/24/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcrinst: HP OpenView IT/Operations A.04.04 (06/24/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/install/opcnsl: HP OpenView IT/Operations A.04.04 PHSS_15672 (06/24/ 98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/perf_alxp.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/mwa_read.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/actions/mailq_pr.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/actions/st_inetd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/actions/st_mail.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/actions/pv.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/actions/itogpm.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/cmds/opcdf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/cmds/opclpst.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/cmds/opcps.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/A.04.04/RPC_NCS/monitor/opcfwtmp.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/sun/sparc/ sunos/AgentPlatform: None /opt/OV/OpC/examples/progs/Makef.sunos: None cksum(1) Output: 2861192664 6207209 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/opc_pkg.Z 1845792877 26618 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/install/ opcrclchk 895615119 28941 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/install/ opcrdschk 2526122735 6222 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/install/ opcrndchk 4138790174 6454 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/install/ opcroschk 2706275903 27236 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/install/ opcrverchk 2558393124 87326 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/install/ opcrinst 223862646 147456 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/install/ opcnsl 3306018211 2539 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/monitor/ ana_disk.sh.Z 628025894 5676 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/monitor/ cpu_mon.sh.Z 4057191499 5915 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/monitor/ disk_mon.sh.Z 312623518 5784 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/monitor/ last_logs.sh.Z 3889363530 5759 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/monitor/ mailq_l.sh.Z 3966366093 3152 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/monitor/ perf_alxp.sh.Z 2363982735 5810 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/monitor/ proc_mon.sh.Z 2348497362 5338 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/monitor/ sh_procs.sh.Z 2340474465 5710 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/monitor/ swap_mon.sh.Z 2200182666 5585 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/monitor/ vp_chk.sh.Z 798936205 5766 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/monitor/ mwa_read.sh.Z 700076308 2524 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/actions/ mailq_pr.sh.Z 1123807317 2548 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/actions/ st_inetd.sh.Z 367506983 2564 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/actions/ st_mail.sh.Z 3364448474 5657 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/actions/ pv.sh.Z 1759261324 1373 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/actions/ itogpm.sh.Z 308451362 315 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/cmds/opcdf.Z 2801172335 328 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/cmds/ opclpst.Z 298286688 354 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/cmds/opcps.Z 1882156236 122211 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/A.04.04/RPC_NCS/monitor/ opcfwtmp.Z 34229012 4070 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/sun/sparc/sunos/AgentPlatform 3014242815 1276 /opt/OV/OpC/examples/progs/Makef.sunos Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: None Patch Package Size: 6690 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_15672 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_15672.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_15672.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_15672. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_15672.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_15672.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o You may use this patch with the following official ITO releases: A.04.0x o DO NOT use this patch with older releases of OpC or ITO, for example versions A.01.X, A.02.X or A.03.X. o This patch provides the HP OV IT/Operations Intelligent Agent to be used with a ITO 4.0x Management Server system, Oracle, English version. (A) Patch Installation Instructions ------------------------------- (A1) Install the patch, following the standard installation instructions. Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license restrictions and limitation of liability and warranties, before installing this patch. ------------------------------------------------------ 1. Back up your system before installing a patch. (you may use opc_backup) 2. Login as root. 3. Copy the patch to your /tmp directory and unshar it: # cd /tmp # sh PHSS_15672 4. For a standalone system, run swinstall to install the patch: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWINSTALL. # swinstall -x match_target=true \ -s /tmp/PHSS_15672.depot It is recommended that you move the PHSS_15672.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: # dd if=/tmp/PHSS_15672.depot of=/dev/rmt/0m bs=2k NOTE: This patch must be installed on the ITO Management Server system, NOT on an ITO Managed Node directly. Changes will take effect on managed nodes by means of ITO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the ITO Administrator's Reference manual for more information. (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_15672 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. # swremove PHSS_15672