Patch Name: PHSS_15267 Patch Description: s700_800 10.X OV ITO4.0X HP-UX 9.x Agent Patch Creation Date: 98/07/03 Post Date: 98/07/08 Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OpenView IT/Operations 4.0 Filesets: OVOPC-CLT.OVOPC-UX-CLT78 Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_15267 Symptoms: PHSS_15267: - opcmsga error: bulk transfer from agent to server may fail with 'interrupted system call' for agents using NCS communication. - Scheduled actions are not executed at 00:xx in April - 'opcagt -status' sometimes hangs - logfile encapsulator problem: truncated message appear in the browser - agent installation fails if there is no opc_op user, but opcgrp is already in NIS or NIS+. - agent didn't work with ECS (Event Correlation) version A.02.15 (which is needed for Y2K compliance) PHSS_14251: - Multiple message (opcmsg) templates get intermixed condition processing. This happens when an agent has multiple opcmsg templates assigned. In this case the contents of matched messages can resemble messages that should actually get supressed. Other symptoms of this bug can be a core dumping message interceptor (opcmsgi) or message agent (opcmsga). - Monitor agent does not use the pipe monagtp, so the growing pipe wastes network/streams buffer resources. PHSS_12687: - Distribution agent coredumps when distributing ECS circuits. - Error during subagent installation: Can't create tmp files. - If respmgr file contains short hostname of the managment server or the OPC_RESOLVE_IP switch is enabled the send_data from the management server fails. Defect Description: PHSS_15267: check the list of the symptoms PHSS_14251: check the list of the symptoms PHSS_12687: check the list of the symptoms SR: B700028407 1653251173 1653261289 Patch Files: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/perf_alxp.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/mwa_read.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/dist_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/ltf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/lbtf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/opcnprcs.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/perf_alxp.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/mwa_read.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/dist_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/ltf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/lbtf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/opcnprcs.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/cmds/opc_sec_v.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/actions/mailq_pr.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/actions/st_inetd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/actions/st_mail.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/actions/pv.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/actions/dist_del.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/actions/itogpm.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/AgentPlatform /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux/AgentPlatform what(1) Output: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/install/opcrclchk: HP OpenView IT/Operations A.04.04 (06/26/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/install/opcrdschk: HP OpenView IT/Operations A.04.04 (06/26/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/install/opcrndchk: HP OpenView IT/Operations A.04.04 (06/26/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/install/opcroschk: HP OpenView IT/Operations A.04.04 (06/26/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/install/opcrverchk: HP OpenView IT/Operations A.04.04 (06/26/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/install/opcrinst: HP OpenView IT/Operations A.04.04 (06/26/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/install/opcrclchk: HP OpenView IT/Operations A.04.04 (06/26/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/install/opcrdschk: HP OpenView IT/Operations A.04.04 (06/26/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/install/opcrndchk: HP OpenView IT/Operations A.04.04 (06/26/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/install/opcroschk: HP OpenView IT/Operations A.04.04 (06/26/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/install/opcrverchk: HP OpenView IT/Operations A.04.04 (06/26/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/install/opcrinst: HP OpenView IT/Operations A.04.04 (06/26/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/perf_alxp.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/mwa_read.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/dist_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/ltf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/lbtf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/monitor/opcnprcs.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/perf_alxp.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/mwa_read.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/dist_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/ltf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/lbtf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_DCE_TCP/monitor/opcnprcs.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/cmds/opcdf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/cmds/opclpst.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/cmds/opcps.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/cmds/opc_sec_v.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/actions/mailq_pr.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/actions/st_inetd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/actions/st_mail.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/actions/pv.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/actions/dist_del.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/A.04.04/RPC_NCS/actions/itogpm.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux/AgentPlatform: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux/AgentPlatform: None cksum(1) Output: 1366466117 4632052 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/opc_pkg.Z 1061166980 2941859 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/opc_pkg.Z 3965864787 26367 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/install/ opcrclchk 2743347777 30077 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/install/ opcrdschk 3549248101 6527 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/install/ opcrndchk 1296620786 5916 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/install/ opcroschk 1500844173 28813 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/install/ opcrverchk 25935965 100497 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/install/ opcrinst 3965864787 26367 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/install/ opcrclchk 2743347777 30077 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/install/ opcrdschk 3549248101 6527 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/install/ opcrndchk 1296620786 5916 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/install/ opcroschk 1500844173 28813 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/install/ opcrverchk 3705950771 100475 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/install/ opcrinst 33785785 2540 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ ana_disk.sh.Z 1014671478 6211 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ cpu_mon.sh.Z 622447803 6676 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ disk_mon.sh.Z 3308320365 6287 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ last_logs.sh.Z 2167643388 6271 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ mailq_l.sh.Z 155009207 3169 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ perf_alxp.sh.Z 2375054717 6435 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ proc_mon.sh.Z 896537086 5886 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ sh_procs.sh.Z 368547266 6360 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ swap_mon.sh.Z 3967429540 6136 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ vp_chk.sh.Z 2834922920 6304 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ mwa_read.sh.Z 2294708544 6539 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ dist_mon.sh.Z 1011743299 11185 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ltf.Z 1011743299 11185 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/lbtf.Z 206210825 89727 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/monitor/ opcnprcs.Z 33785785 2540 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ ana_disk.sh.Z 1014671478 6211 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ cpu_mon.sh.Z 622447803 6676 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ disk_mon.sh.Z 3308320365 6287 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ last_logs.sh.Z 2167643388 6271 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ mailq_l.sh.Z 155009207 3169 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ perf_alxp.sh.Z 2375054717 6435 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ proc_mon.sh.Z 896537086 5886 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ sh_procs.sh.Z 368547266 6360 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ swap_mon.sh.Z 3967429540 6136 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ vp_chk.sh.Z 2834922920 6304 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ mwa_read.sh.Z 2294708544 6539 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ dist_mon.sh.Z 2484141816 11323 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ ltf.Z 2484141816 11323 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ lbtf.Z 3916741982 7449 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_DCE_TCP/monitor/ opcnprcs.Z 3377928457 315 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/cmds/opcdf.Z 2785093162 328 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/cmds/opclpst.Z 462581988 354 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/cmds/opcps.Z 2309784975 13623 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/cmds/ opc_sec_v.sh.Z 3754806019 2522 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/actions/ mailq_pr.sh.Z 182103014 2543 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/actions/ st_inetd.sh.Z 2992860781 2563 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/actions/ st_mail.sh.Z 3523655469 6190 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/actions/pv.sh.Z 1017492280 6529 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/actions/ dist_del.sh.Z 3601925734 1373 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/A.04.04/RPC_NCS/actions/ itogpm.sh.Z 879810418 4485 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux/AgentPlatform 957436232 4483 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s800/hp-ux/AgentPlatform Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_12687 PHSS_14251 Equivalent Patches: None Patch Package Size: 8260 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_15267 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_15267.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_15267.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_15267. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_15267.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_15267.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o You may use this patch with the following official ITO releases: A.04.0x o DO NOT use this patch with older releases of OpC or ITO, for example versions A.01.X, A.02.X or A.03.X. o This patch provides the HP OV IT/Operations Intelligent Agent to be used with a ITO 4.0x Management Server system, Oracle, English and Japanese version. (A) Patch Installation Instructions ------------------------------- (A1) Install the patch, following the standard installation instructions. Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license restrictions and limitation of liability and warranties, before installing this patch. ------------------------------------------------------ 1. Back up your system before installing a patch. (you may use opc_backup) 2. Login as root. 3. Copy the patch to your /tmp directory and unshar it: # cd /tmp # sh PHSS_15267 4. For a standalone system, run swinstall to install the patch: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWINSTALL. # swinstall -x match_target=true \ -s /tmp/PHSS_15267.depot It is recommended that you move the PHSS_15267.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: # dd if=/tmp/PHSS_15267.depot of=/dev/rmt/0m bs=2k NOTE: This patch must be installed on the ITO Management Server system, NOT on an ITO Managed Node directly. Changes will take effect on managed nodes by means of ITO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the ITO Administrator's Reference manual for more information. (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_15267 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. # swremove PHSS_15267