Patch Name: PHSS_14109 Patch Description: s700_800 10.X OV ITO3.0X HP-UX 11.x Agent Patch Creation Date: 98/03/11 Post Date: 98/03/26 Hardware Platforms - OS Releases: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Products: OpenView IT/Operations 3.0X Filesets: OVOPC-CLT.OVOPC-UX10-CLT Automatic Reboot?: No Status: General Release Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_14109 Symptoms: PHSS_14109: - ITO 3.0X didn't support agent installation on HP-UX 11.x. This patches introduces this new agent platform for use with the ITO 3.0X managament server. Defect Description: PHSS_14109: - see list of symptoms above. SR: 0000000000 Patch Files: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/install/opcrclchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/install/opcrdschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/install/opcrndchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/install/opcroschk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/install/opcrverchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/install/opcrinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/ana_disk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/cpu_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/disk_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/last_logs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/mailq_l.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/perf_alxp.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/proc_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/run_dmesg.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/sh_procs.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/swap_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/vp_chk.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/mwa_read.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/dist_mon.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/opcfwtmp.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/opcnprcs.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/actions/mailq_pr.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/actions/st_inetd.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/actions/st_mail.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/actions/pv.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/actions/dist_del.sh.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/cmds/opcdf.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/cmds/opclpst.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/cmds/opcps.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/AgentPlatform /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux11/AgentPlatform /opt/OV/OpC/examples/progs/Makef.hpux11 what(1) Output: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/install/opcrclchk: HP OpenView IT/Operations A.03.10 (02/06/98) OpC A.03.10 (02/06/98) OpC A.03.10 (02/06/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/install/opcrdschk: HP OpenView IT/Operations A.03.10 (02/06/98) OpC A.03.10 (02/06/98) OpC A.03.10 (02/06/98) OpC A.03.10 (02/06/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/install/opcrndchk: HP OpenView IT/Operations A.03.10 (02/06/98) OpC A.03.10 (02/06/98) OpC A.03.10 (02/06/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/install/opcroschk: HP OpenView IT/Operations A.03.10 (02/06/98) OpC A.03.10 (02/06/98) OpC A.03.10 (02/06/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/install/opcrverchk: HP OpenView IT/Operations A.03.10 (02/06/98) OpC A.03.10 (02/06/98) OpC A.03.10 (02/06/98) OpC A.03.10 (02/06/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/install/opcrinst: HP OpenView IT/Operations A.03.10 (02/06/98) OpC A.03.10 (02/06/98) OpC A.03.10 (02/06/98) OpC A.03.10 (02/06/98) /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/ana_disk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/cpu_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/disk_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/last_logs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/mailq_l.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/perf_alxp.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/proc_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/run_dmesg.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/sh_procs.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/swap_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/vp_chk.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/mwa_read.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/dist_mon.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/opcfwtmp.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/monitor/opcnprcs.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/actions/mailq_pr.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/actions/st_inetd.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/actions/st_mail.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/actions/pv.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/actions/dist_del.sh.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/cmds/opcdf.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/cmds/opclpst.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/A.03.10/cmds/opcps.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s700/ hp-ux11/AgentPlatform: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s800/ hp-ux11/AgentPlatform: None /opt/OV/OpC/examples/progs/Makef.hpux11: OpC A.03.10 (02/09/98) cksum(1) Output: 4006708766 2483988 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/opc_pkg.Z 3401569562 6905 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/install/opcrclchk 2366957582 28728 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/install/opcrdschk 4009750598 6670 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/install/opcrndchk 1025926653 6298 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/install/opcroschk 618760076 25861 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/install/opcrverchk 2870376432 84217 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/install/opcrinst 2720422979 2584 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/ana_disk.sh.Z 3682866894 4628 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/cpu_mon.sh.Z 2678847664 4651 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/disk_mon.sh.Z 3302366515 4540 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/ last_logs.sh.Z 2127616542 4507 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/mailq_l.sh.Z 2042423820 3143 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/ perf_alxp.sh.Z 3796703047 4682 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/proc_mon.sh.Z 3368676172 4330 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/ run_dmesg.sh.Z 889134818 4109 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/sh_procs.sh.Z 878783858 4631 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/swap_mon.sh.Z 3330501505 4363 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/vp_chk.sh.Z 1047503980 4544 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/mwa_read.sh.Z 1403909931 4823 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/dist_mon.sh.Z 1460468053 5528 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/opcfwtmp.Z 1886799537 5008 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/monitor/opcnprcs.Z 2632539201 2572 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/actions/mailq_pr.sh.Z 2190269828 2560 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/actions/st_inetd.sh.Z 3759003457 2591 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/actions/st_mail.sh.Z 75659383 4445 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/actions/pv.sh.Z 3096461674 4822 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/actions/dist_del.sh.Z 2655067088 348 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/cmds/opcdf.Z 2903278317 360 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/cmds/opclpst.Z 1888334751 388 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/A.03.10/cmds/opcps.Z 2698618949 4740 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s700/hp-ux11/AgentPlatform 1825821118 4724 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s800/hp-ux11/AgentPlatform 1885028789 1505 /opt/OV/OpC/examples/progs/Makef.hpux11 Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: None Patch Package Size: 2790 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_14109 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_14109.depot 5b. For a homogeneous NFS Diskless cluster run swcluster on the server to install the patch on the server and the clients: swcluster -i -b This will invoke swcluster in the interactive mode and force all clients to be shut down. WARNING: All cluster clients must be shut down prior to the patch installation. Installing the patch while the clients are booted is unsupported and can lead to serious problems. The swcluster command will invoke an swinstall session in which you must specify: alternate root path - default is /export/shared_root/OS_700 source depot path - /tmp/PHSS_14109.depot To complete the installation, select the patch by choosing "Actions -> Match What Target Has" and then "Actions -> Install" from the Menubar. 5c. For a heterogeneous NFS Diskless cluster: - run swinstall on the server as in step 5a to install the patch on the cluster server. - run swcluster on the server as in step 5b to install the patch on the cluster clients. By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_14109. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. Warning: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_14109.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_14109.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o You may use this patch with the following official ITO releases: A.03.00 A.03.01 o DO NOT use this patch with older releases of OpC or ITO, for example versions A.01.X or A.02.X or with newer releases like ITO A.04.00 o This patch provides the HP OV IT/Operations Intelligent Agent to be used with a ITO 3.0 Management Server system on HP-UX 10.x, Oracle, English and Japanese version. o The new HP-UX 11.x agent support will be added to the existing HP-UX 10.x client fileset OVOPC-CLT.OVOPC-UX10-CLT Note that you will lose the HP-UX 11.x support if you deinstall this HP-UX 10.x client fileset from your ITO Management Server system. o If you eventually upgrade to ITO 4, you need the PHSS_13550 patch containing the ITO 4 agent for HP-UX 11.x support. Please deinstall the current PHSS_14109 patch before installing PHSS_13550 to avoid problems (i.e. if you deinstall PHSS_14109 later, it will remove files necessary for the ITO 4 HP-UX 11.x agent) o The ITO HP-UX 11.00 agent runs on 32 and 64 bit systems, but does NOT take advantage of the following features of HP-UX 11.0: - does not support 64 bit applications - does not support kernel threads - does not allow to use nsswitch.conf to switch between files/nis/nisplus for passwd, group and aliases data - does not support NFS diskless clusters because this is not supported with HP-UX 11.00 o There are no additional default message source templates available for HP-UX 11.0. Use the ITO default templates for HP-UX 10.x. o Installation prerequisites for the ITO HP-UX 11.0 agent software are the same as for the ITO HP-UX 10.x agents. See Chapter 1 of the HP OV ITO Administrator's Reference for information about managed node prerequisites, and Chapter 2 for installation tips. o The agent SD software structure on HP-UX 11.00 is OVOPC-AGT.OVOPC-UX11 (A) Patch Installation Instructions ------------------------------- (A1) Stop the ITO administrator user interface processes running on the machine. - Stop all the ITO Administrator GUI that are running, by using the "File:Exit" menubar item (A2) Install the patch, following the standard installation instructions. Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license restrictions and limitation of liability and warranties, before installing this patch. ------------------------------------------------------ 1. Optionally back up your system before installing a patch. (you may use opc_backup) 2. Login as root. 3. Copy the patch to your /tmp directory and unshar it: # cd /tmp # sh PHSS_14109 4. For a standalone system, run swinstall to install the patch: # swinstall -x match_target=true \ -s /tmp/PHSS_14109.depot It is recommended that you move the PHSS_14109.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: # dd if=/tmp/PHSS_14109.depot of=/dev/rmt/0m bs=2k (A3) Load the ITO agent configuration into the database: # /opt/OV/bin/OpC/opcagtdbcfg -p hp/s700/hp-ux11 -d # /opt/OV/bin/OpC/opcagtdbcfg -p hp/s800/hp-ux11 -d (A4) After installing PHSS_14109, restart the ITO Administrator user interface processes on your Management Server system. NOTE: This patch must be installed on the ITO Management Server system, NOT on an ITO Managed Node directly. Changes will take effect on managed nodes by means of ITO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the ITO Administrator's Reference manual for more information. (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_14109 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. # swremove PHSS_14109 (B2) If you have no HP-UX 11.0 agent installed anymore remove the HP-UX 11.0 platforms from the database by executing: # /opt/OV/bin/OpC/opcagtdbcfg -p hp/s700/hp-ux11 -r # /opt/OV/bin/OpC/opcagtdbcfg -p hp/s800/hp-ux11 -r